Brand Name : SINOHERO

Model Number : AcuitSign M6

Certification : CE, ISO. Declaration of Conformity

Place of Origin : CHINA

Payment Terms : L/C, D/P, T/T, Western Union

Delivery Time : 10 working days

Power Input : ≦150VA

Safety class : Category I

Standard module slot : 4

Size : 422mm×213mm×362mm

Resolution : 1280×800 pixels

Input Current : 1.7~0.8V

Contact Now

Technical Specifications of AcuitSign M6

Size and Weight

  • Size:422mm×213mm×362mm
  • Weight:≦11kg
  • Standard module slot:4
  • Additional module rack Slot:1

Power supply

  • Power Voltage: AC 100-240V 50/60Hz
  • Power Input: ≦150VA
  • Input Current:1.7~0.8V
  • Safety class: Category I

Display

  • 14.1〞 Color TFT-LCD
  • Resolution:1280×800 pixels

Battery (Option)

  • Type: Rechargeable Lithium battery,11.1V/4.0AH
  • Operating time under the normal use and full charge:≧60minutes

(2 batteries for 120 minutes)

Recorder (Option)

  • Method: Thermal dot array
  • Paper width:50mm(1.97 in)
  • Paper length:15m
  • Paper Speed:12.5/25/50(mm/sec)
  • Traces: Maximum 3 tracks
  • Recording way: Real-time recording, Periodic recording, Alarm recording

Alarm

  • Level: Low, medium and high
  • Indication: Auditory and visual
  • Patient Physiological Alarm Light color: Yellow & Red
  • Equipment Technical Alarm Light color: Blue
  • Supports Pitch Tone and multi-level volume
  • Supports custom arrhythmia tone

Input device

  • Touch screen (Option).
  • knob: standard config
  • Mouse input: Support
  • Keyboard input: Support

System Output & Extensible Interfaces

  • Ethernet Network:2 Standard RJ45 socket
  • Defibrillation Output:1 RJ11 socket
  • Nurse Call:1 BNC socket
  • Video Output:1 DVI port,1VGA port
  • USB1.1 port:6
  • Auxiliary Module Rack connector: 1
  • SD memory card:2G (standard config)
  • Analog Output(ECG or IBP):Option

Trend & Reviewing

  • Trend:168 hours
  • NIBP measurement reviewing:1000 groups
  • ARR event:128 groups of ARR event and the associated waveform
  • Alarm events:128 groups of parameter alarm events and associated parameter
  • Waveform at the alarm moment

Holographic waveform: The storage time depends on the stored waveforms and

the quantity of them.

Environment

  • Operating temperature:0~+40℃
  • Storage temperature:-20℃ to +50℃
  • Operating humisity:15%to85%(non condensing)
  • Storage humidity :10% to 93%(non condensing)
  • Operating atmospheric pressure:860hPa to 1060hPa
  • Storage atmospheric pressure:500hPa to 1060hPa

Safety:

  • IEC60601-1 Approved, CE marking according to MDD93/42/EEC

ECG

  • Lead Mode:3-leads ECG input

5-leads ECG input

12-leads ECG input

  • Lead selection:Ⅰ,Ⅱ,Ⅲ

Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V-

Ⅰ,Ⅱ,Ⅲ, aVR,aVL,aVF,V1~V6(option)

  • Gain: 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1),

20mm/mV(×2), 40mm/mV(×4),Auto

  • CMRR: Monitor mode≧105dB

Surgery mode≦105dB

Diagnostic mode≧90dB

  • Frequency response(-3d B):

Monitor mode 0.5~40Hz

Surgery mode 1~25Hz

Diagnostic mode 0.05~150Hz

  • input impedance: ≧5.0Mohm
  • ECG signal range:±10.0mV
  • Electrode offset potential: ±500mV
  • Patient Leakage Current:<10uA
  • Standardizing signal:1mV±5%
  • Baseline recovery:<5s after Defibrillation.(Mon or Surg mode)
  • Indication of electrode separation: Every electrode(exclusive of RL)
  • Protection: Breakdown Voltage 4000AVC 50/60Hz;defibrillator proof
  • Sweep speed:12.5mm/s,25mm/s,50mm/s

HR

  • Range: Adult 10~300bpm

Pediatric & Neonate:10~350bpm

  • Refreshing time:≦50 bpm per 2 pulses

50~120bpm per 4 pulses

≧120bpm per 6 pulses

  • Resolution: 1bpm
  • Accuracy: ±1% or ±1bpm,whichever is greater

ST segment

  • Measurement range:-2.0mV~2.0mV
  • Accuracy:-0.8mV~0.8mV: ±0.02mV or ±10% whichever is greater

Over ±0.8mV:unspecified

  • Resolution:0.01mV

RESP

  • Method: Thoracic impedance
  • Lead Selected from:Ⅰ(RA-LA)orⅡ(RA-LL);Default:Ⅰ
  • Gain:×0.25, ×1, ×2, ×4
  • Bandwidth:0.25Hz to 2.0Hz (-3dB)
  • Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s
  • Measurement Range:0~150 rpm
  • Resolution: 1rpm
  • Accuracy:±2rpm or 2% whichever is greater
  • Delay of Apnea Alarm:10s,15s,25s,30s,35s,40s,45s,50s,55s,60s

NIBP

  • Way of measurement: Automatic oscillometry
  • Range of measurement:

Adult: SYS 30~270mmHg

DIA 10~220mmHg

MAP 20~235mmHg

Child: SYS 30~235mmHg

DIA 10~220mmHg

MAP 20~225mmHg

Neonate: SYS 30~135mmHg

DIA 10~100mmHg

MAP 20~125mmHg

  • Cuff pressure range:0~300mmHg
  • Resolution:1mmHg
  • Pressure Accuracy: Static:±2% or ±3mmHg,whichecer is greater

Clinical: ±5mmHg average error

Standard deviation:≦8mmHg

  • Unit: mmHg, kPa
  • Measurement mode: Manual, Auto, STAT
  • Intervals for AUTO measurement time:1,2,3,4,5,10,15,30,60,90 minutes;

2,4,8,12hours

  • STAT mode cycle time: keep 5 minutes, at 5 seconds interval.
  • Overpressure Protection: Hardware and software double protections
  • Pulse rate range:40~240bpm

Standard SpO2(Digital)

  • Measurement Range:0~100%
  • Resolution:1%
  • Accuracy: At70~100%,±2%

At0~69%,unspecified

PR

  • Measurement Range:25~255bpm
  • Resolution:1bpm
  • Accuracy: ±1% or ±1bpm,whichever is greater

Nellcor-SpO2

  • Measurement Range:0~100%
  • Resolution:1%
  • Accuracy:At70~100%:±2%(Adult)

At70~100%:±3%(Neonate)

At70~100%:±2%(Low Perfusion)

At0~69%,unspecified

PR

  • Measurement Range:20~300bpm
  • Resolution:1bpm
  • Accuracy: 20bpm to 250bpm: ±3bpm

251bpm to 300bpm: unspecified

Masimo-SpO2

  • Measurement Range:0% to 100%
  • Resolution:1%
  • Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion conditions)

70% to 100%:±3%(neonate,non-motion conditions)

70% to 100%:±3%(motion conditions)

0% to 69%, unspecified

  • Average time:2-4s,4-6s,8s,10s,12s,14s,16s

PR

  • Measurement Range:25bpm to 24bpm
  • Accuracy: ±3bpm(non-motion conditions)

±5bpm(motion conditions)

  • Resolution:1bpm

TEMP

  • Max Channel: 8
  • Measurement way: Thermal resistance way
  • Measurement Range: 0.0℃~50.0℃(32℉~122℉)
  • Accuracy:±0.1℃ or ±1℉(exclusive of probe)
  • Resolution: 0.1℃ or 1℉
  • Unit: Celsius(℃),Fahrenheit(℉)
  • Connecting cable: Compatible with YSI-400 serial

IBP

- Max Channel: 8

- Measurement way: Directly invasive pressure measurement

- Sensitivity of transducer: 5uV/V/mmHg, ±2%

- Impedance of transducer: 300 to 3000Ω

- Measurement Range: -50~+350mmHg

- Resolution: 1mmHg

- Unit: mmHg, kpa, cmH2O

- Accuracy:

Static: ±1mmHg or ±2%, whichever is grater(exclusive of transducer)

±4mmHg or ±4%, whichever is grater(inclusion of transducer)

Dynamic:±4mmHg or 4%, whichever is grater

Transducer sites: Arterial Pressure (ART)

Pulmonary Artery Pressure (PA)

Left Atrium Pressure (LAP)

Right Atrium Pressure (RAP)

Central Venous Pressure (CVP)

Intracranial Pressure (ICP)

P1/P2

  • Selection of measurement range:

ART:0~+350mmHg

PA:-10~+120mmHg

CVP/RAP/LAP/ICP:-10~+40mmHg

P1/P2:-50~+350mmHg

EtCO2(Sidestream)

  • Measure method: Infrared spectrum
  • Measure Range: 0.0~13.1%(0~99.6mmHg)
  • Resolution: 1mmHg
  • Unit: %,mmHg,kpa
  • Accuracy: 0% to 4.9%,±0.3%(±2.0mmHg)

5.0%to 13.1%,<±10%of the reading

  • Measurement range of awRR:3~150rpm
  • Calibration: Offset calibration:auto,manual,Gain calibration

EtCO2(Mainstream)

  • Measure method: Infrared spectrum
  • Warm up time: Capnogram displayed in less than 15 seconds,At an ambient

Temperature of 25℃, full specifications within 2 minutes.

  • Measure Range: 0.0~19.7%(0~150mmHg)
  • Resolution: 1mmHg
  • Rise time(10l/min):≦60ms
  • Unit: %,mmHg,kpa
  • CO2 Accuracy:0-40mmHg, ±2mmHg

41-70mmHg, ±5% of reading

71-100mmHg, ±8% of reading

101-150mmHg, ±10% of reading

(at 760 mmHg,ambient temperature of 35℃)

  • awRR measurement range:0~150rpm
  • awRR measurement Accuracy: ±1rpm

EtCO2(Microstream)

  • Measure method: Infrared spectrum
  • Warm up time: Capnogram displayed in less than 20 seconds, At an ambient

Temperature of 25℃,full specifications within 2 minutes.

  • Measure Range: 0.0-19.7%(0-150mmHg)
  • Resolution: 1mmHg
  • Unit: %,mmHg,kpa
  • CO2 Accuracy: 0-40mmHg, ±2mmHg

41-70mmHg, ±5% of reading

71-100mmHg, ±8% of reading

101-150mmHg, ±10% of reading

(At 760 mmHg,ambient temperature of 25℃)

(When RR>80 rpm, all the rang is ±12% of reading)

CO2 response time: <3S

  • awRR measurement range:2~150rpm
  • awRR measurement Accuracy: ±1rpm
  • Sample Flow Rate:50ml/min ±10ml/min

Multi Gas

  • Measure method: Infrared spectrum
  • Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,NEF,SEV,DES)
  • Resolution:1%
  • Unit:%
  • Calibration: Room air calibration automatically when changing airway

Adapter (<5 sec)

  • Warm-up time:<10S,full accuracy within 1min
  • Measurement and alarm range of AG
  • Gas Range Accuracy

CO2 0-10% ±(0.3% ABS+4%REL)

N2O 0-100% ±(2% ABS+8%REL)

O2 10-100% ±(2% ABS+2%REL)

HAL,ISO,ENF 0-5% ±(0.15% ABS+10%REL)

SEV 0-8% ±(0.15% ABS+10%REL)

DES 0-18% ±(0.15% ABS+10%REL)

  • awRR measurement range: 0~150rpm
  • awRR measurement Accuracy: ±1rpm
  • Rise time(flowing speed 10I/min)CO2≦90ms

O2≦300ms

N2O≦300ms

Hal,Iso,Enf,Sev,Des≦300ms

  • Total system response time :<1seconds

Noninvasive Cardio Output (ICG):

Method: Measurement of thoracic electrical bioimpedanc

  • Measurement Range:HR:40~250bpm

SV:5~250ml

SI:5~125ml/m2

C.O.:1.4~15L/mm

TFC:15~143KΩ

  • Accuracy: HR±2bpm

SV: unspecified

C.O unspecified

  • Alarm range: C.L.:0.0L/min/m2 to 15.0 L/min/m2 continuously adjustable

TFC: 10/KΩ to 150/kΩ continuously adjustable.

Standard Configuration of AcuitSign M6:

Mainunt:14.1″Anti-glare TFT-LCD display,4 Standard module slot,1Additional module rack Slot(for EMS all-in-one module), 2 RJ45 internet socket,1 Defibrillation Outpit,1 Nurse Call socket,1 DVI port,1VGA port,6 USB1.1 port,1 Auxiliary Module Rack connector,2G SD memory card.

Option of AcuitSign M6:

EMS module:8 Kinds of option

Option Module: Sidesteam CO2 module, Microstream CO2 module, Mainstream CO2 module, AG module, ICG module, IBP module, Temp module, , Nellcor SpO2 module, Masimo SpO2 module

Module Rack: Auxiliary Module Rack

Navigating: USB compatible mouse and keyboard.

Printing: 3 Channel Thermal Recorder

Mounting: Rolling stand, Wall mount

Battery:11.1V/4.0AH Rechargeable Lithium Battery (max 2 pcs),

Other options: External Display, Wireless Lan, Extensive Memory card, Analog Output (ECG or IBP), Full Touch Screen


Product Tags:

patient care monitoring system

      

hospital patient monitoring equipment

      
Quality AcuitSign M6 Modular Patient Monitor For Central Monitoring System for sale

AcuitSign M6 Modular Patient Monitor For Central Monitoring System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHENZHEN CHANGKE CONNECT ELECTRONICS CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)